What Does Monogram Dryer Error Code E5 Mean?

Error code E5 on a Monogram dryer indicates an open circuit in the outlet thermistor. The outlet thermistor monitors exhaust air temperature and is critical for determining when laundry is dry and preventing overheating. An open-circuit outlet thermistor sends no signal to the control board — causing E5 and stopping the drying cycle as a safety precaution.

Common Causes of E5

  • Failed outlet thermistor element (open circuit internally)
  • Disconnected or broken wiring to the outlet thermistor
  • Corroded connector pins
  • Damaged control board input circuit

How to Troubleshoot E5

  1. Power reset: Unplug for 60 seconds. Reconnect and check whether E5 clears on restart.
  2. Locate the outlet thermistor: It is typically mounted on the exhaust duct at the drum outlet, near the blower wheel housing or lint duct.
  3. Inspect wiring and connector: Trace the wiring from the thermistor to the board. Look for a broken wire, unplugged connector, or burned pins. Reseat any loose connections.
  4. Measure thermistor resistance: Disconnect the thermistor and test with a multimeter. Infinite resistance at room temperature confirms the thermistor is open and must be replaced.
  5. Replace with OEM part: Use a genuine Monogram outlet thermistor. Ensure the connector engages fully and the thermistor is secured in its mounting bracket.

For professional Monogram dryer repair, call our team at 844-752-7887 — we carry genuine thermistor assemblies for all Monogram dryer models.

Need Help? If the error code hasn't resolved after basic troubleshooting, call our certified Monogram technicians at 844-752-7887 for professional diagnosis and same-day repair.